CritCoolA Link4 company

1.0  The hall

Cooling controls for critical facilities.

We make critical cooling easier. CritCool brings the controls Link4 has built for commercial growers since 2004 to the coolant loops of liquid-cooled data centers.

A leak detection cable under a raised floor with a water droplet on it, an isolation valve behind.

2.0  Detect

A leak on a cold plate loop is a race.

Find it at the cable.

Close the right valves.

Tell the building which rack.

The sequence runs in the controller, in the time it takes a valve to turn.

3.0  Isolate

Pick a rack. Watch it isolate.

One row, eight racks, one coolant loop. Click any rack to put a leak on it. The controller closes that rack's supply and return valves, trips its breaker and keeps the other seven cooling.

CDU CDU-1 SUPPLY RETURN

Swipe the sheet sideways to see the whole row.

Sheet M-601. Row A, liquid cooled. Simulation.Example timing, not a test result.

4.0  Hold

Held inside the window.

A liquid-cooling loop is written to a chemistry window. CritCool measures conductivity, flow and pressure continuously and doses to hold the loop inside it, the way Link4 doses nutrients for growers.

Upper limitLower limit 00:0012:0024:00 Conductivity, loop A
Last reading 412 µS/cmDoses 0Example trace. Not real data.
Since 2004Controls for commercial growers.
Since 2012Cloud connected controllers.
FourIsolated Modbus ports on every Pearl controller.
AnaheimAssembled in USA.

5.0  Supply

Products and services.

Each one says what it does in its name and speaks the protocols your building already uses. The products are in development, and we are looking for pilot sites.

A leak isolation panel at the end of a row of racks.

LeakLockLX-16

Finds the leak, closes the right valve, names the rack.

Speaks
Modbus TCP, BACnet/IP, MQTT
Status
In development. Pilot sites wanted.
A side-stream coolant conditioning panel with a sight glass, sensor and dosing pump.

CoolantGuardCG-25

Keeps a coolant loop inside its PG25 limits, and proves it.

Speaks
Modbus TCP, BACnet/IP, MQTT
Status
In development. Pilot sites wanted.
DIN rail I/O modules with network cables and status lights.

Critical I/O

Point I/O for CDUs, pump skids and leak zones, with the points list already written.

Speaks
Modbus TCP and RTU, BACnet/IP, MQTT
Status
In development. Pilot sites wanted.
An open control panel with orderly wiring and DIN rail modules in a test bay.

PanelWorks

Control panels built to print. Their panels are built in Link4's own UL508A shop in Anaheim.

Builds
Pump, fan and valve panels
Status
Building panels today.
Cooling towers at dusk with a chemical feed skid in front.

TowerDoseTD-4

Cooling tower chemistry control under your own brand.

For
Water treatment companies
Status
In development. Pilot sites wanted.
Inside a commercial glass greenhouse at night, rows of plants and heating pipes.

HeatShareHS-1

Datacenter heat, metered into a greenhouse.

For
Sites with a grower next door
Status
In development. Pilot sites wanted.

Services

Controls integration

Sequences written, points mapped, and integrated with your building system.

With
Your BMS and EPMS teams
Status
Available.

Field installation

In California, Link4 is the licensed electrical contractor, C-10 licence 1093344.

Where
California
Status
Available.

Commissioning support

Startup and functional testing alongside your commissioning agent.

With
Your Cx agent
Status
Available.

6.0  Origin

Growing is mission critical too.

Since 2004 Link4 has built the controllers that keep commercial greenhouses alive: heating, cooling, venting, irrigation and fertigation, on sites where a few degrees can cost a crop. A crop cannot be restarted. That is the discipline CritCool brings to the data hall.

Run a greenhouse Link4 controls. Example readings. Not real data.Open full screen
At dusk, a data center beside a glass greenhouse lit from inside, joined by a heat pipe bridge.

Datacenter heat can warm a greenhouse. HeatShare is how.

7.0  Submittal

Tell us about the loop. We will send the submittal.

A person at Link4 reads every request. You will hear back from a named engineer, not a mailing list.

What do you need?